維港口腔
Contact Us

+852 6637 2280(Hongkong/whatsApp)

+86 132 6696 2280(Shenzhen)

維港口腔福田皇崗院/福田下沙院/羅湖區委院/羅湖國貿院/珠海拱北院

維港口腔
Contact Us

+852 6637 2280(Hongkong/whatsApp)

+86 132 6696 2280(Shenzhen)

维港口腔连锁
維港矯正優勢
深圳維港口腔
知名牙科品牌
深圳種植牙價格
深圳補牙費用
深圳種植牙费用
01 Vickong disinfection specification

The instruments used in dental treatment may be placed in the mouth, and thorough disinfection can ensure the safety of the patient. All instruments used in Victoria Vickong Dental cavity are individually packaged and strictly sterilized for use by patients. Moreover, the number of instruments can be replaced first to ensure the disinfection quality of each set of instruments, and the basic disinfection time of each package is at least 60 minutes or more.

Why not use disposable equipment?

In clinical practice, doctors need sophisticated instruments to assist diagnosis, although the price of disposable devices is low, but because of poor precision, it can not meet the requirements of the Vickong Dental standards and expectations, and the disinfection effect is uncertain, will affect the quality of treatment, so Vickong Dental should not be considered for use.

02 Vickong Dental disinfection and bacteria reduction method
03 Vickong Clinic disinfection

In order to ensure the quality of medical treatment, the clinic must be re-disinfected after each visit. In the dental treatment environment, doctors, assistants, tables, treatment chairs, and lamps can all cause cross-infection. Vickong Dental Oral care in terms of infection control, after each clinic use, it takes at least 7-15 minutes to re-disinfect and arrange for the next patient to use. In order to protect your health and safety, Victoria Vickong Dental has spent a lot of attention on manpower, time and cost.

深圳植牙&深圳維港口腔
Vickong clinic disinfection process
1.Wash the table, sink, spittoon and wipe down every corner of the treatment chair
2.Spray every place with disinfectant for medical purposes
3.Wipe the wet disinfectant clean with sterile dry gauze
4.Replace the head cover of the therapy chair
5.Apply anti-cross infection tape
6.Provide a safe and clean treatment environment
04 Vickong oral instrument disinfection
深圳植牙&深圳維港口腔

1.The disinfectant solution was soaked for more than 60 minutes and then subjected to ultrasonic heating and shock for 15 minutes

2.Each instrument should be thoroughly cleaned under running water, and anything remaining on the surface should be washed away

3.Drain and wipe dry

4.The equipment is classified and packaged, which is convenient to put into the bacteria-reducing pot and avoid the contamination of the equipment after bacteria-reducing

5.Put into automatic pre-vacuum high temperature and high pressure bacteria-reducing pot for disinfection

6.Clean instruments after sterilizing and reducing bacteria

05 Vickong Dental CT-Room disinfection
深圳植牙&深圳維港口腔
Vickong CT room disinfection process
1.Wipe the chair and back clean, and then spray the chair back, chair surface and CT machine with medical disinfectant
2.Wipe the wet disinfectant with sterile gauze
3.Tape the CT machine to prevent cross infection
4.CT outdoor control buttons are also affixed with cross-infection prevention tape
06 Vickong Dental oral disinfection equipment

High temperatures can kill microorganisms, and steam with high humidity and temperature is the most effective and environmentally friendly disinfection method. As long as the vapor can penetrate into the cracks and pipes of the device, the vapor will be the most effective method of sterilization.

What will affect the vapor's access to the inside of the device?

The answer is "air." For example, the air remaining in the tubular instrument will prevent the vapor from entering the disinfection interior, so it is important to remove the air before disinfection (pre-vacuum), the sterilization chamber in the disinfection pot must be completely vacuum to ensure that the vapor can penetrate the most sophisticated tools (high speed and low speed or porous tools).

Vickong Disinfection equipment - steam sterilizer
peculiarity

The use of efficient vacuum system, the limit vacuum reaches -90KPA or more, the evacuation speed is fast, the drying effect is good, and the sterilization is more thorough.

Built-in instant steam generator, steam generator to produce steam speed, high quality.

Sterilized high efficiency air screening program to ensure that the air that breaks the vacuum is sterile air to avoid the re-contamination of sterile items. Water injection, pulsating vacuum, temperature rise, sterilization, exhaust steam, vacuum drying process automatic operation.

维港口腔连锁